Installation Manual
TV Automatic Foundation Vents
Specifying a Temp-Vent System
Powered Temp-Vent - Foundation Vent
Model: TVHPS6
For homes that require a higher rate of airflow, the Power Temp Vent is the ideal choice. Powered vents are quick, convenient and economical when it comes to controlling moisture and odor problems. Air is suctioned out of the crawl space and replaced with fresh outside air. Negative pressure helps prevent dampness and odor from rising into living areas of the home.
-
8" x 16" to fit into a standard block opening
-
Completely screened, front and back
-
No mortar required for installation
-
Three-prong plug for easy hook-up
-
Totally enclosed, thermally protected motor
-
U.L. recognized and CSA certified
-
3000 rpm, 115VAC 8 amps
-
11,160 cubic ft./hr.
-
Black, Brown, Gray
FIVE YEAR FACTORY WARRANTY
Calculating how many foundation vents are needed:
Example: 1500 sq/ft crawl space x 3 feet high = 4500 cu/ft x 6 = 27,400 / 7,200 = 3.74. Thus, install 4 power vents with intake vents on the opposite side.
Totally enclosed motor feature a 3-prong plug and is 0.017 HP rated for continuous operation. UL recognized and CSA certified.
Power vents should be placed on one side of the house with non-powered vents that act as intake vents on the other sides.
A Thermostat should be used to turn the fan off in freezing weather to protect pipes under the home and save energy. A Humidistat should also be connected to the fan to control the operation of the vent. A damp weather shut-off humidistat will turn the unit off when it's raining outside.
A Duct System is available that attaches to a powered foundation vent to provide targeted ventilation in hard to reach areas.
Please refer to and follow instructions on Power Temp-Vent label.
call the sales department at 1-800-788-4142.